Xi 400

Compact spot finder IR camera Xi 400

The newly developed optris Xi 400 combines the benefits of a robust, compact pyrometer and an advanced IR camera. The 80 Hz frame rate allows for the monitoring of fast thermal processes, even including a line-scan function. The spot finder IR camera has an optical resolution of 382 x 288 pixels and comes with an extensive ready-to-use package - including a versatile image processing software.

Due to its compact design and an affordable pricing, the new optris Xi spot finder IR camera is ideally suited for OEM applications.

Important specifications

  • Motorized focus
  • Suberb distance-to-spot-size
    ratio up to 390:1
  • Frame rate: 80 Hz

From $2,500.00

Technical details of the optris Xi 400

 

  • Scope of supply:
    Process imager Xi 400
    USB cable (1 m)
    Standard PIF cable (1 m) incl. terminal block
    Mounting bracket with nut
    Software package optris PIX Connect
  • Detector: FPA, uncooled (17 µm pitch)
  • Optical resolution: 382 x 288 pixels
  • Spectral range: 8 – 14 µm
  • Temperature range (scalable via programming keys or software):
    –20 °C … 100 °C (–4 … 212 °F)
    0 °C … 250 °C (32 … 482 °F)
    (20) 150 °C … 900 °C (302 … 1652 °F) 1)
    200 °C … 1500 °C (390 … 2732 °F) (option)
  • Frame rate: 80 Hz / 27 Hz
  • Optics:
    18° x 14° (f = 20) [0.79]
    29° x 22° (f = 12.7) [0.50]
    53° x 38° (f = 7.7) [0.30]
    80° x 54° (f = 5.7) [0.22]
  • Macro optics:
    18° x 14° (f = 20 mm), smallest measuring spot: 90 µm
  • Focus: Manual motor focus
  • Distance-to-spot ratio: 390:1 (18° optics)
  • Thermal sensitivity (NETD): 80 mK
  • System accuracy (at ambient temperature 23 ± 5°C [73.4 ±41 °F]): ±2 °C or ±2 % (±4 °F or ±2 %), whichever is greater
  • PC interface: USB 2.0 / optional USB to GigE (PoE) conversion
  • Process interface (PIF):
    Standard PIF:
    0–10 V input, digital input (max. 24 V), 0–10 V output
    Industrial PIF:
    2x 0 – 10 V input, digital input (max. 24 V),
    3x 0/4-20 mA output, 3x relay (0 – 30 V/ 400 mA), fail-safe relay
  • Cable length (USB): 1 m (3.3 ft) (standard), 3 m (9.8 ft), 5 m (16.4 ft), 10 m (32.8 ft), 20 m (65.6 ft)
  • Ambient temperature (TAmb): 0 °C…50 °C (32 °F to 122 °F)
  • Relative humidity: 10 – 95 %, non-condensing
  • Enclosure (size / rating):Ø 36 mm x 100 mm (Ø 1.42 in x 3.9 in) (M30x1 thread) / IP 67 (NEMA 4)
  • Weight (without mounting bracket): 216 – 220 g (7.6 – 7.7 oz) (depending on lens)
  • Shock 2): IEC 60068-2-27 (25 G and 50 G)
  • Vibration 2):
    • IEC 60068-2-6 (sinus shaped)
    • IEC 60068-2-64 (broadband noise)
  • Tripod mount: 1/4-20 UNC
  • Power supply: USB powered

 

1) Accuracy statement effective from 150 °C
2) For more details see operator’s manual

Accessories